Hyper-V live migrations causes bugcheck Reboot


i have hyper-v cluster consisting of 3 lenovo x3650's servers. when attempt live migrate work other times server reboot bugcheck bugcheck was: 0x00000101 (0x0000000000000005, 0x0000000000000000, 0xffffc1800b400180, 0x0000000000000016).

minidump shows problem ntoskrnl.exe

it seems happened quite server 2008 , 5500 series processors none of cures seem working. server has sp xeon e5-2630  servers stable otherwise

i have tried changing power management etc without success

hi,

want confirm below details:
1. the bugcheck reboot problem happens on physical machine.
2. the os version windows server 2008 r2.

please open cmd , run “sfc /scannow” check/repair system files.

check see if hotfix mentioned in below kbs helpful (windows server 2008 r2).

stop error message on windows server 2008 r2-based computer has hyper-v role installed , uses 1 or more intel cpus code-named nehalem: "0x00000101 - clock_watchdog_timeout":
https://support.microsoft.com/en-us/help/975530/stop-error-message-on-a-windows-server-2008-r2-based-computer-that-has-the-hyper-v-role-installed-and-that-uses-one-or-more-intel-cpus-that-are-code-named-nehalem-0x00000101---clock-watchdog-timeout

"0x00000101" stop error occurs in windows 7 or in windows server 2008 r2 if usb 2.0 debug cable attached:
https://support.microsoft.com/en-us/help/2648039/-0x00000101-stop-error-occurs-in-windows-7-or-in-windows-server-2008-r2-if-a-usb-2.0-debug-cable-is-attached

best regards,
eve wang

please remember mark replies answers if help.
if have feedback technet subscriber support, contact tnmff@microsoft.com.