Event ID 46 The time service encountered an error and was forced to shut down. The error was: 0x800706BB: The RPC server is too busy to complete this operation.
after installing july 2009 windows patches on dcs, following day began receive errors on system designated role of pdc. starts after following service enables: the winhttp web proxy auto-discovery service service sent start control.
about 5-10 minutes after informational message appears then the time service stops followed win32 service , browers service, etc. dc becomes unusable , has hard rebooted. tried resolve issue moving role dc, issue happened on other dc also. can help, or give me idea how can resolve problem?
thanks,
wayne
about 5-10 minutes after informational message appears then the time service stops followed win32 service , browers service, etc. dc becomes unusable , has hard rebooted. tried resolve issue moving role dc, issue happened on other dc also. can help, or give me idea how can resolve problem?
thanks,
wayne
hello sarath... after applying hotfix -
http://support.microsoft.com/kb/932762 . our dcs... problem resolved.
thanks
wayne wonder